ROTOFAN FLUSHING FOR INTERNAL SAJ WATER 6″ LINE – 250METERS LOTTE CHEMICAL TITAN
FST, awarded a internal ROTOFAN flushing job for Lotte Chemical Titan (M) Sdn Bhd located at Pasir Gudang Johor.
Workscope :
- To provision 12 000psi high pressure diesel driven unit with high flow 185lpm capacity to hydro flushing internal of related SAJ line from battery point.
- Flushing self rotating 3d nozzle system to cater id 100mm – 250mm equipped with roto track, speed controller & hose protector system to flush down the internal of pipe to remove any foreign matter which formed and to ensure 100% cleanliness. A T4 nozzle was used to flush the wide dia pipe which consisted 10 bend and the pipe lenght appeox 250meters.
- To perform mechanical work on flanges and fittings opening, blinding & de blinding work during the maintenance cleaning.
- Job completed successfully box back after all related sludge/mud was thoroughly house keeping and hand over upon satisfactory of LCTM own flushing.
Technology Applied :
- High pressure flushing pump at 12000psi /390HP cater 185lpm with self rotating 3d concrete cutting nozzle with applied back pushers nozzle system for ID 250mm
- Roto track with 175cfm air supply T4 pneumatic hose driven system for 35meters height